Single Acting Hydraulic Power Unit for Dump Trailers
  • Single Acting Hydraulic Power Unit for Dump Trailers Single Acting Hydraulic Power Unit for Dump Trailers
  • Single Acting Hydraulic Power Unit for Dump Trailers Single Acting Hydraulic Power Unit for Dump Trailers

Single Acting Hydraulic Power Unit for Dump Trailers

Model:HCPGS

HCPGS is a 1.2 GPM single-acting hydraulic power unit with an SAE #6 port, 4-gallon tank and 3,000 PSI specification for dump trailer systems.

  • Type:

    Single acting
  • Flow:

    1.2 GPM
  • Port size:

    SAE #6
  • Tank size:

    4 Gal
  • Pressure specification:

    3,000 PSI

Send Inquiry

Product Description

The HCPGS single acting hydraulic power unit for dump trailers is designed for circuits that power the lifting direction and use the machine's own weight or a separate return arrangement for lowering. The HCIC catalog lists this model as a single-acting unit with 1.2 GPM flow, an SAE #6 port, a 4-gallon tank, 3,000 PSI and a solenoid-operated 2-way, 2-position valve.

That combination is useful when the trailer needs a straightforward power-up circuit rather than hydraulic power in both cylinder directions. The right application still depends on the cylinder, load path, trailer geometry, battery system, hose routing and control method.

hydraulic power unit


I. HCPGS Specifications

Item Catalog information
Model HCPGS
Type Single acting
Flow 1.2 GPM
Port size SAE #6
Tank size 4 Gal
Pressure specification 3,000 PSI
Valving Solenoid operated; 2‑way, 2‑position
Catalog source HCIC‑2026, page 16

These are catalog identification values. They should not be treated as a universal lifting capacity, guaranteed speed or complete electrical specification for every trailer.


II. How the HCPGS Circuit Works

A single-acting HPU sends pressurized oil to one working side of the cylinder. When the solenoid valve is energized, the pump supplies flow to raise or extend the connected actuator. When the command is removed, the circuit changes to its return condition according to the selected trailer design. The actual lowering behavior depends on the cylinder type, body weight, mechanical resistance, load-control arrangement and return path.

This is the main difference between a single-acting unit and a power-up/power-down circuit. If the trailer requires the HPU to drive the cylinder in both directions, the single-acting HCPGS configuration is not automatically the correct choice. The cylinder and control sequence should be checked before ordering.


III. Product Features That Matter in a Trailer Installation

3.1--Simple single-acting control

The 2-way, 2-position solenoid valve gives the HCPGS a focused control arrangement for a single-acting circuit. That can make the hydraulic schematic easier to review when the trailer only needs powered lifting and a defined lowering path.

3.2--1.2 GPM catalog flow

The listed flow is a starting point for speed estimation. Actual trailer movement depends on cylinder volume, load, valve restriction, hose length, battery condition and the flow available at the cylinder port. Do not convert the catalog flow directly into a guaranteed dump time without checking the complete system.

3.3--4-gallon tank

The 4-gallon tank provides the reservoir volume listed for this model. The required operating oil level must be checked against the cylinder volume, hose volume, installation angle, return condition and available service space. The tank value alone does not confirm that every cylinder and trailer body will be compatible.

3.4--SAE #6 port connection

The SAE #6 port must be matched with the hose, adapter and fitting standard used on the trailer. Confirm thread identification, sealing method, hose bend radius and access for tightening before the unit is installed inside a toolbox or frame compartment.

3.5--Compact trailer integration

The HCPGS is listed in HCIC's dump-trailer HPU section. For a practical installation, the buyer should still confirm mounting holes, motor and reservoir clearance, battery cable routing, remote-control location and protection from road debris.


IV. Where This HPU Fits

The HCPGS can be reviewed for dump trailers and related equipment using a single-acting hydraulic circuit. It may suit an OEM trailer build, replacement project or fleet repair when the connected cylinder and lowering method match the application.

It is not a universal replacement for a double-acting power unit. A trailer using powered retraction, a hydraulic jack circuit or a two-direction control sequence may require a different valve configuration.


V. What to Confirm Before Ordering

Send the following information with an HCPGS inquiry:


  1. Cylinder bore, rod diameter and stroke
  2. Cylinder type and mounting arrangement
  3. Required extension and lowering sequence
  4. Trailer body weight and load path information
  5. Battery voltage and available cable length
  6. Hose length, port standard and fitting details
  7. Available mounting space and protection requirements
  8. Whether the pump is shared with a jack or another hydraulic function
  9. Photos of the current unit and nameplate, if this is a replacement


This information allows the HPU to be reviewed as part of the trailer system instead of being selected only by tank size or pressure.


VI. FAQ

HCPGS FAQ
The HCIC-2026 catalog lists HCPGS as a single‑acting hydraulic power unit.
The catalog lists 1.2 GPM and 3,000 PSI for HCPGS. These are catalog specifications, not a guaranteed trailer cycle time or lifting capacity.
The catalog lists a 4‑gallon tank. Final oil level and system compatibility should be checked with the connected cylinder and circuit.
HCPGS uses a solenoid‑operated 2‑way, 2‑position valve according to the catalog.
No. The connected cylinder, lowering method, electrical supply, mounting space and required control sequence must be confirmed before selection.


VII. Conclusion

The HCPGS single acting hydraulic power unit for dump trailers is a defined catalog option for a power-up circuit. Its key identification points are the single-acting type, 1.2 GPM flow, SAE #6 port, 4-gallon tank, 3,000 PSI specification and 2-way, 2-position solenoid valve.

For a reliable quotation, provide the cylinder data, trailer layout, electrical supply and lowering sequence. HCIC can then review whether the HCPGS configuration matches the complete hydraulic system.


VIII. About HCIC

HCIC supplies hydraulic cylinders, hydraulic power units and related hydraulic components for transportation, waste-handling, construction and industrial equipment. Final product suitability should be confirmed against the complete machine design and applicable safety requirements.

hydraulic cylinders

Hot Tags: Single Acting Hydraulic Power Unit for Dump Trailers

Related Category

Send Inquiry

Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy